| Models & Specifications |
Manufacturers |
SONOMED, U.S.A. |
SONOMED, U.S.A. |
Specifications |
|
|
Models |
EZ 5500 A/B |
|
| Display |
TFT Active Matrix color LCD 6.5" 640x480 pixels |
|
| Video |
RS-170 BNC for video printer VCR and remote viewing |
|
| Size |
12.5"x3.25"10.0" |
|
| Weight |
2.4kg |
|
| Voltage |
100/120/220/240 volts and 50 Hz or 60Hz sensed by input voltage |
|
| Printer |
High Resolution Video Printer |
|
| Date/time |
Built in Clock Calendar |
|
| Data entry |
Full Alpha Numeric via touch screen |
|
| Specifications |
|
|
| Probe Frequency |
10MHz 30frames/sec |
|
| Range |
Automatic mode 18-46mm, Manual mode 0.5-35mm |
|
| Accuracy |
Clinical +- 0.1mm, Electronic +- 0.023mm |
|
| IOL Formulas |
Binkhorst, Holladay, Theoretic/T & Regression-II, Hoffer-Q and Haigis (optional) |
|
| Liquid Crystal Display |
TFT Active Matrix color LCD 6.5" 640x480 pixels |
|
| Calibration |
Automatic with Built in Cylinder |
|
| Storage |
Stores 5 Scans and Measurements |
|
| Modes |
Automatic, Manual and Diagnostic |
|
| Voltage |
100/120/220/240 Volts and 50Hz auto sensed by Input voltage |
|
| Power |
|
|
| Size |
12.5"x3.25"10.0" |
|
| Weight |
2.4kg |
|
| Additional Features |
Amplifier,Magnification, Processing |
|
| Specifications |
300A |
A 5500 |
| Probe Frequency |
10MHz |
10MHz |
| Range |
|
Automatic mode 18-33mm, Manual mode 0.5-35mm |
| Accuracy |
Clinical +-0.1mm, Electroninc +-0.0484mm |
Clinical +- 0.1mm, Electronic +- 0.0375mm |
| IOL Formulas |
Binkhorst, Holladay, Theoretic/T & Regression-II, Hoffer-Q |
Any 3 only Binkhorst, Holladay, Theoretic/T & Regression-II, Hoffer-Q |
| Liquid Crystal Display |
Touch Screen, Large High Resolution backlit LCD |
7" B&W CRT monitor |
| Calibration |
Automatic with Built in Cylinder |
Automatic with Built in Cylinder |
| Storage |
Permanent storage of 5scans for later review and IOL calculation |
Stores 5 Scans and Measurements |
| Modes |
Cataract,Dense cataract, Aphakic, Seudophakic, Manual gain control |
Automatic, Manual and Diagnostic |
| Voltage |
90-250 VAC |
100/120/220/240 Volts and 50Hz auto sensed by Input voltage |
| Power |
5watts |
|
| Size |
|
14.5"x6"x13.5"x |
| Weight |
|
23 pounds, 10.4kg |
| |
|
|
Models |
|
300 - P |
| |
|
Automatic Measurement Algorithm Senses When Probe Properly Aligned (Acceptance Angle 10º)
Average and Standard Deviation Computed for Each Reading (Reading Comprised of 256 Individual Measurements)
Multiple Corneal Maps with Graphical Display
Map 1: 1 Point / Single Scan
Map 2: 1 Point / Multiple Scans
Map 3: 5 Point / Single Scan
Map 4: 5 Point / Multiple Scans
Measurement Range 125 to 1000 Microns
Measurement Review Mode
Central Corneal Thickness (CCT) Corrected IOP
Selectable Variable Corneal Velocity
Selectable Bias
Automatic Calibration Check
Built-In Probe Sensitivity Test
Measurement Accuracy Test (±1 micron)
20 MHz Probe
Straight or 45º Angled Probe Styles Available
Electronic Accuracy ±1 micron
Clinical Accuracy ±5 microns |
| Pachymeter specs |
Automatic Measurement Algorithm Senses When Probe Properly Aligned (Acceptance Angle 10º)
Average and Standard Deviation Computed for Each Reading (Reading Comprised of 256 Individual Measurements)
Multiple Corneal Maps with Graphical Display
Map 1: 1 Point / Single Scan
Map 2: 1 Point / Multiple Scans
Map 3: 5 Point / Single Scan
Map 4: 5 Point / Multiple Scans
Measurement Range 125 to 1000 Microns
Measurement Review Mode
Central Corneal Thickness (CCT) Corrected IOP
Selectable Variable Corneal Velocity
Selectable Bias
Automatic Calibration Check
Built-In Probe Sensitivity Test
Measurement Accuracy Test (±1 micron)
20 MHz Probe
Straight or 45º Angled Probe Styles Available
Electronic Accuracy ±1 micron
Clinical Accuracy ±5 microns |
|
| Models & Specifications |
Manufacturers |
|
SONOMED, U.S.A. |
| Display |
|
LCD |
System Features & Specification |
|
VuMAX - II |
|
|
HF 35 (UBM) Probe |
| Type |
|
Motor-driven, compact interchangeable transducers |
| Transducer frequency |
|
35 MHZ / 50 MHZ |
| Scanning Methods |
|
Variable field sector scanner |
| Sector Angle |
|
38° or 20° fields |
| Scanning Speed |
|
38° or 20° fields |
| Observable Range (Variable) |
|
18.5mm Widex14mm deep in 38° field
12.0mm Widex14mm deep in 20° field |
| Display |
|
Dual screen simultaneous display with live zoom and standard screen display |
| Electronic Resolution |
|
|
| In 38° field sector |
|
Axial : 0.027mm
Lateral: 0.035mm |
| In 20° field sector |
|
Axial 0.027mm
Lateral 0.023mm |
| Acoustic Axial Resolution |
|
|
| 35 Mhz Transducer |
|
0.035mm |
| 50 Mhz Transducer |
|
|
| Gain Curves |
|
Logarithmic with user-selectable window(contrast) and level (brightness) control |
| Measurements |
|
|
| Distance Measurements |
|
Angle-to-angle, sulcus-to-sulcus, corneal thickness, and scleral thickness |
| Anterior Segment Biometry |
|
Single measurement of cornea thickness, anterior chamber depth(ACD), and lens thickness
A-Scan profile with two markers/dual caliper Measurements.
Angle in degrees |
| Dynamic Recording |
|
Scancap kit (4-Different sizes) |
| Scan Time |
|
45 seconds (depending on RAM) |
| Recording Frame Rate |
|
12.5 or 25 fps |
| Electrical |
|
|
| Voltage |
|
90-240 VAC |
| Frequency |
|
50/60 Hz |
| Maximum Current |
|
6.5 A (low voltage range) or
3.5 A(high voltage range) |
| Monitor |
|
|
| Type |
|
Liquid crystal display (LCD) flat panel monitor |
| Viewable size |
|
17" |
| Resolution |
|
1024x768 |
| Pixel pitch |
|
0.297mm |
| Contrast Ratio |
|
450:1 |
| Features and Options include : |
|
CPU with Multi Frequency Cable
JPEG Saving Function
Unlimited Recording Capability Through Video clips
Patient and Images. Software can be upgraded |
| Computer |
|
17" Hx8.9"Wx18.4" D |
| Monitor |
|
15.8"Hx16.1"Wx6.7" D |
| Dimensions |
|
|
| Computer |
|
17" Hx8.9"Wx18.4" D |
| Monitor |
|
15.8"Hx16.1"Wx6.7" D |
| Dimensions |
|
|
| Computer |
|
45 lbs |
| Monitor |
|
11.5 lbs |
| B-Scan Probe |
|
10 Mhz / 20 Mhz |