Lasers |
|
|

<< Click on image to enlarge >> |
|
| Model
Number : |
Q-las 10,Classic A, Classic A/L, ClassicK, ClassicK/R ,Erylas, KTP - 532nm,Krypton Lasers, Trabeculas, Classic G , Classic K |
| |
|
| Detail
Description : |
Different types of Laser are available for Skin treatment, Hair removal, surgical, ENT etc. Laser for various applications of treatments are also available. The Various applications are:
Dermatology : skin resurfacing, refreshing, vascular lesions, pigmented lesions, hair removal etc
Dental/ENT/Surgery : bleaching, soft tissue, caries detection and removal, general surgery, tumor removal etc
Urology/Gynecology : tumor removal, laproscopy etc |
| |
|
|
|
|
|
| View Product Range |
|
|
|
Diode Laser |
Erbium |
Krypton Laser |
| |
|
|
| Models & Specifications |
A.R.C. Lasers, GERMANY |
| Model |
Q-las 10 |
Classic A, Classic A/L, ClassicK, ClassicK/R |
Erylas |
KTP - 532nm |
Krypton Lasers |
Trabeculas |
Classic G |
Classic K |
| Application in |
Photodisruption (Ophthalmology) |
Dermatology, ENT, Ophthalmology, Dental |
Dermatology, Ophthalmology |
Dermatology, ENT, Opthalmology, Dental |
Dermatology, HNO, Ophthalmology |
Ohthal- mology |
|
|
| Mode of Application |
Photodisruptor |
Photocoagulator |
Erbium Lasers |
Nuvolas |
Flexilas |
|
Photo- coagulator |
Photo- oagulation |
| Lasers |
Nd:YAG |
Argon, Krypton and Mixed |
Er:Yag |
Frequency doubled Nd:YAG |
|
Frequency doubled Nd:YAG |
Frequency doubled Nd:YAG |
Krypton, dual Lasers tubes |
| Wavelength |
1064nm |
488-514/ 520-568/ 520-568-647 |
2.94microm |
532nm green |
520nm,
530nm
(green),
568nm
(yellow) |
532nm |
532nm |
520nm Green, 567nm Yellow, 647nm Red, 520-567nm White |
Mode Structure |
Quasi Gauss |
blue-green, blue-green, green-yellow, green-yellow-red |
|
|
|
|
|
|
Focus Spot |
15 microns |
Optic
Spotsize parfocal 50-
500micron
in all |
dia 0.2-
0.5-
1.0mm |
|
Spot size 0.25-0.5-1.0mm |
Spot size 400micron at |
|
|
Cone angle |
16deg |
|
|
|
|
3,2degrees |
|
|
Rep. Rate |
1 pulse per second |
0.02ms - infiniti |
Adjustable 1Hz to 15Hz |
1-6Hz Frequency |
adjustable 0.05-3.0sec + CW |
1Hz on demand |
1-5Hz |
1-5Hz |
Pulse length |
4ns |
0.02ms -infiniti |
Max pulse energy 1.5J |
2ms-CW (Adjustable) |
adjustable 0.05-1.0sec + Single Pulse |
3ns |
Adjustable 10ms to CW, 80steps |
0.02ms - CW |
Plasma formation in air |
<4mJ |
|
|
|
|
|
|
|
Q-switch mode |
passive |
|
|
|
|
Q-switched |
|
|
Cooling |
Air |
Water; 2.5l/min / AIR |
Internal water to air |
Internal air cooling |
External Water (4l/min) |
|
Forced Air |
Water, 5 liters per minute |
Output Energy |
25mJ max. at 3 pulses |
4, 2, 2, 2-2 |
22.5W |
3.0W |
2.5W(all line) - 1.3W (yellow) |
|
>1.5W |
|
Micro Manipulator |
|
Electric HS |
|
|
|
|
50-500micron parfocal |
50-500micron parfocal |
Energy Adjustable in steps |
0.5, 0.7, 1, 1.3, 1.6, 2.0, 3.0, 5.0, 7.0, 10mJ |
|
|
|
|
|
|
|
Burst Mode Adjustable |
Steps x2 or x3 |
|
|
|
|
|
|
|
Aiming Beam |
Dual Diode beam 635nm |
630nm - red |
Diode Lasers Red |
635nm (red) 1mW |
5W White light (incoherent) |
Red diode, adjustable intensity |
Red diode (638nm) |
Red, adjustable |
Micro-offset |
0-150-300micro |
|
|
|
|
|
|
|
Display |
|
|
Digital Touch Screen |
Removable remote control with digital screen |
|
|
|
|
Slit Lamp |
Haag Streit BQ |
HS-BQ/BM |
|
Optial delivery 300microm flexible fibre |
|
HS BQ |
Slit lamp
with 5step Magnifi-
cation
|
HS BQ |
Power Rrequire-ments |
250W |
400v-16A 3Phase |
200-240VAC,
16Amps,
50/60Hz
|
230v, 5A / 115V, 10A |
400V/16A 3-Phase |
110-230V, 50/60Hz,
3A at
230V |
220V,6A / 110V,
2A |
400V 20A per
Phase |
Voltage Require-ments |
85-260V |
|
|
|
|
|
|
|
| Weight with Slitlamp |
32kg |
50kg/40kg/75kg |
85kg |
12kg |
70kg |
53kg |
15kg |
97kg |
| Footprint with slitlamp |
0.5sqm |
|
|
|
|
0.5sqm |
|
|
| Accessories Standard |
|
|
|
Lightweight carrying case, 2safety eyewear |
|
|
|
|
| Accessories Optional |
|
|
|
Barefibers, Scanner |
|
|
Endoprobes, Heine LIO |
|
|
|